Choose a target for your location
Natural Resources Canada groups recommendations by heating degree-day zone. The data used by this tool lists RSI 7.9 for zone 4, RSI 9.7 for zone 5, RSI 10.6 for zone 6 and RSI 14.1 for zones 7a, 7b and 8. These are national recommendations shown as guidance. Confirm the zone and applicable requirements for your home rather than inferring a target from a city name alone.
The tool asks for a target RSI directly and does not determine a postal-code zone or code compliance. Existing insulation, roof construction, ventilation and local amendments matter. If an energy retrofit is being planned, verify the complete assembly and target with current government guidance or a qualified energy professional.
Measure existing insulation
Measure the attic floor area and the depth of existing insulation at several points without compressing it. Note gaps, settled areas, eaves, hatches, ducts and stored items. The quantity tool estimates one added blown-fibreglass product layer from area and a selected target. It does not subtract existing material or model irregular floor area.
Air leakage and moisture problems should be addressed before adding insulation. Look for signs of roof leaks or condensation and understand the ventilation paths. Keep the eaves clear and check the location of electrical, gas and heat-producing equipment. A professional assessment may be needed where these conditions are uncertain.
How the Climate Pro chart becomes bags
The Johns Manville Climate Pro card gives discrete RSI rows with minimum bags per 100 m². When a target falls between available product rows, the calculator selects the next listed RSI at or above it. For a 9.7 target, the next row is RSI 9.8, listed at 29.1 minimum bags per 100 m² and 472 mm minimum thickness.
For a 100 m² example, 100 ÷ 100 × 29.1 equals 29.1 bags, which rounds up to 30 whole 14.3 kg bags. The selected chart row is a product layer estimate. It is not proof that the result meets a provincial code or that the attic can accept this installed depth.
Safety and installation details
The source material lists clearances from heat-emitting devices and recessed light fixtures. Maintain the clearance that applies to the exact product and local requirements, and do not cover recessed lights or other heat sources without an approved detail. NRCan’s attic guidance also emphasizes air leakage, moisture and ventilation considerations.
Blown insulation generally requires equipment and an installation method that can affect the installed depth and coverage. Follow the manufacturer’s current bag instructions and do not assume the chart reflects every cavity, obstruction or installation condition. Ask a qualified installer to check wiring, combustion appliances and the existing roof assembly.
What this estimate leaves out
The calculator does not model existing insulation combinations, compressed or wet material, attic geometry, waste, settling, air sealing, ventilation or equipment setup. The published bag chart is for the named Climate Pro product and should not be applied to a different brand. The final count can change when an installer assesses the attic and the exact system.
Use the result to prepare questions and a preliminary quantity. Before buying, check the current manufacturer card and bag label, confirm the target for the location, and have suitability reviewed where the work affects electrical, fire, moisture or ventilation safety.
Before you finalize the estimate
Keep the target selection and material order as two separate decisions. First confirm the heating degree-day zone and target guidance that applies to the home. Then choose a product whose charted RSI and bag rate suit that target. A larger chart row can exceed the target because products are sold in discrete layers, but more material is not automatically suitable if it affects clearances or ventilation.
If a contractor proposes a different brand, ask for that brand’s current coverage card and installed depth calculation. Do not convert Climate Pro bags directly to another product. Record existing insulation and air leakage observations for the installer, and ask how those conditions affect the recommended retrofit.
A clear attic estimate should identify the chosen heating degree-day zone, target RSI, product chart row, attic area and whole-bag rounding. That record makes the assumptions reviewable and lets you compare a contractor’s quote on the same basis. If the installer recommends air sealing or ventilation work first, include that scope separately. The insulation bag count by itself does not describe a complete energy retrofit.
Make it your project.
Use the supporting calculator with your measured dimensions and the product you plan to buy. Read its worked example, sources and assumptions before ordering.
Frequently asked questions
What RSI should an attic have in Canada?
NRCan recommendations vary by heating degree-day zone. The cited data lists RSI 7.9 to 14.1 across zones 4 through 8, but check the current recommendation and requirements for your location.
How many bags cover 100 m² at RSI 9.7?
The Climate Pro chart row selected is RSI 9.8 at 29.1 minimum bags per 100 m², so the calculator rounds the 100 m² example to 30 bags.
Does the calculator subtract existing insulation?
No. The Canadian tool estimates a single product layer from the target you enter. Existing insulation needs separate assessment.
Does RSI 9.8 mean my attic meets code?
No. It identifies a manufacturer product row, not a code-compliance decision.
Can I blow insulation over wiring and recessed lights?
Clearances and approved details depend on the equipment and product. Follow current instructions and consult a qualified professional if unsure.
For general information only, not professional advice. Rules and prices change, so check the official sources below. Use your own judgement and speak to a qualified builder or engineer before you act.